DocNo.FM0411issueJPage19
18.REMOTEOFFSITESETUP
FromtheProgrammingmenu,select“RemoteOffsiteSetup”tosettheprotocoltype,dialattempts,siteID,parkcharacter,audio
switchingmodeandupto3telephonenumbersforRemoteOffsitemode;
Enterthefollowing;
ProtocolType*:choosewhatdataformatthecontrol
centreuses,TTNew=01,BS7369=02,BS8521=03andTT92=04 .
DialAttempts:setthenumberoftimeseachnumberwillbedialledifnotanswered,default03,canbechangedfrom01to06.
SiteIdentity:entertheuniquesiteidentitynumberissuedbythecontrolcentre,max4digits.
ParkCharacter:defaultFF=remoteoffsiteparkdisabled.Ifrequired;settheDTMFcharacterusedbythecontrolcentretoparkfaulty
intercoms,normally05(canbe00to09).
AudioVoxEnable:simplex=01(default)orVox=02.Simplexmeansspeak/listencontrolistoggledmanuallybytheoperator,Voxis
automatic(voiceswitched).
TelephoneNumber001:entertheRemoteOffsitetelephonenumber‐2digitsperbox.
Repeatforupto3RemoteOffsitetelephonenumbers.
LeaveunusedlocationssetasFF.
SecondaryBTLineEnable:normallysetto00.Onlysetto01iftheAdventxtsystemhas2BTlinesconnected(mainandsecondary)via
aBTLineSelectorUnit(P/No.ZXT330).Ifsetto01theDTMFchannel003mustbesettoFFonthe“DTMFChannels”screen.
Click“Submit”toenteranychanges.
*Note:ProtocolTypesTTNew=01andBS7369=02wereremovedinV4.01Afirmware(21April2017)andreinstatedinV4.04A
firmware(23February2018)onward.