DocNo.FM0411issueJPage20
19.SYSTEMTIMERS
FromtheProgrammingmenu,select“SystemTimers”tosetthetimeoutperiodsforcallsinalloperatingmodesandtherepeattime
forExtracareintercoms;
Enterthefollowing;
OnsiteTimeout:themaximumtimeacallcanremainunansweredinonsitemodebeforebeingautomatically
switchedoffsite,default=
0360,canbechangedfrom0001to9999seconds.
OnsiteAudioTimer:themaximumspeechtimeforacallinOnsitemode,default=0360,canbechangedfrom0001to9999 seconds.
LOffsiteHoldTimer:themaximumtimeaLocalOffsitecallwillwaittobeanswered,default0050,canbechangedfrom0001to9999
seconds.
LOffsiteAudioTimer:themaximumspeechtimeforacallinLocalOffsitemode,default=0120,canbechangedfrom0001to9999
seconds.
ROffsiteHoldTimer:themaximumtimeaRemoteOffsitecallwillwaittobeanswered,default0050,canbechangedfrom0001to
9999seconds.
ROffsiteAudioTimer:themaximumspeechtimeforacallinRemoteOffsitemode,default=0360,canbechangedfrom0001to9999
seconds.
ROffsiteCallbackTimer:themaximumspeechtimewhenacontrolcentrecallsaresidentbackinRemoteOffsitemode,default=
0360,canbechangedfrom0001to9999seconds.
DialinLineHoldTimer:themaximumtimethesystemwillwaitbetweenacontrolcentreringinginandcallingaresidentbackin
RemoteOffsitemode,default=0360,canbechangedfrom0001‐9999secs.
BTLineFaultTimer:thedelaybeforetelephonelinefaultisreported,default=120,canbechangedfrom0001 to9999seconds
ExtracareRepeatTime:themaximumtimebetweencancellinganExtracarecallviatheDECThandsetandvisitingtheintercomto
performamanualreset,default15mins,canbechangedfrom0130mins.
BS7369(mS):0600delaybetweendatapacketsfor21CNcompatibilityonBS7369protocol.NotusedinV3.01A/V4.01Aonwards.
OnsiteDutyStartTime:FFFF=disabled,entertimeforthesystemtoautomaticallyselectonsitemode.Use24hourclockandenter
leadingzero’s,eg.0800(8AM).
ROffsiteDutyStartTime:FFFF=disabled,entertimeforthesystemtoautomaticallyselectremoteoffsitemode.Use24hourclockand
enterleadingzero’s,eg.1700(5PM).