23.DOORENTRYSETUP
FromtheProgrammingmenu,select“DoorEntrySetup”tosetthenumberofdoorpanels,speech/locktimers,accesscodes,trade
times,calltransferon/offtimeperiod,printoutenableandfastbusy;
Enterthefollowing;
NumberofDoorPanels:enterthetotalnumberofdigitaldoorpanels,00=noneto16=max.
Note;digitaldoorpanelshavefixedID’sfrom600to615(door1toDoor16)‐thesemustbeenteredaftertheflatnumbersinthe
“TenantsUnitIden tity”menu.Seepage
9ofthismanual.

BSTAdjustment:default=01forautomaticadjustmentofdaylightsavingtime,00=noadjustment.
SpeechTime:enterthemaximumspeechtimeforadoorentrycall,default60seconds,canbechangedfrom0000to02 55seconds.
(Timerterminatedafterlockreleaseorphonehungup).
LockTime:enterthemaximumlockreleasetime,default10seconds,canbechangedfrom0000to0255seconds.(Timerterminated
whendooropenedifdoorstatuscontactisconnected).
PrivacyTime:enterthetelephoneprivacytime,default60minutes,canbechangedfrom0000to0999minutes(0000=on/offprivacy).
AccessCode001to004:enteraccesscodes1to4,defaultFFFF=disabled,any4digitnumber.
RingCycles:enterthenumberoftelephoneringcyclesbeforethedigitaldoorpaneldisplays“NotAvailable‐PleaseTryLater”.Default
=08,canbechangedfrom00to99.
DoorOpenLEDEnable:default=01toilluminatethegreendooropenLEDonalltelephoneswhenthedoorisopened(musthavedoor
statuscontactfitted).00disablesthegreendooropenLED.
TimedCodedAccessEnable:default=00disablestimedaccesscodes(ie.codeswilloperateanytime).01allowsaccesscodesto
functionduringspecifictimeperiodsonly.
TimedAccessCode001to004:entertimedaccesscodes1to4,defaultFFFF=disabled,any4digitnumber.Seebelowforsettingthe
timeperiodsthesecodescanbeused.
AccessCodeOnTime001to004:enterupto4ontimesperdayusing24hourclockformatandenterleadingzero’s,eg.0700,1300,
1630.DefaultFFFF=disabled
AccessCodeOffTime001:enterupto4offtimesperdayusing24hourclockformatandenterleadingzero’s,eg.0700,1300,1630.
DefaultFFFF=disabled
TradeOnTime000to020:enterupto3ontimesperday,000002=Monday,003005=Tuesdayetc.DefaultFFFF=disabled,use24
hourclockandenterleadingzero’s,eg.0700,1300,1630.