‐18‐
2.3PROGRAMMINGPARAMETERSLIS
T
MenuGroup Parameter
Enter
ParameterNo.
Enterthefollowingdata…
Default
Setting
See
Section
LoadDefaults
andParameterCheck
LoadDefaults #000
Entertherequireddefaultparameter
followedby#
N/A
2.3.1
LoadSystem Defaults #001 N/A
LoadRadioDefaults #002 N/A
CheckParameters #003 N/A
AudioSettings
GSMMode #004 0#=Disableor1#=Enable Disabled
2.3.2
SirenVolume #005
Enter0to5followedby#
0#=off,1#=minvolumeto
5#=maxvolume
Level 3
AudioVolume #006 Level3
RingVolume #007 Of
f
AudioMode #008 0#=Simplexor1#=HalfDuplex HalfDuplex
MainsDisconnectionAlert #009
0#=Disableor1#=Enable
Enabled
AssuranceTone #010 Enabled
TelephoneLineFailAlert #011 Enabled
HardwiredInputs
Pullcord #012
Enterhardwiredinputdevicetype
parameterfollowedby#
ForBS8521protocoladdthe
2digitLocationCodefromtheliston
page15beforepressing#
E.g.aheatdetectorinthekitchenon
ahardwiredinputwouldbe#01922#
None
2.3.3
Smoke #013 None
PIRMovementSensor #014 None
DoorExit #015 None
HighTemperature #016 None
LowTemperature #017 None
Gas #018 None
Heat #019 None
CarbonMonoxide #020 None
IdentitySettings
ProtocolType #022 0#=TT or 1#=BS8521 TT
2.3.4
UnitID(max12digits) #024 EntertheunitIDfollowed by# 995
PreAlarmDelay(in4secsteps) #025 00#nodelayto60#max 4Seconds
TelephoneNumbers
TelNo.1(ARC1) #026
EntertheControlCentreTelNo.
(max16digits)followedby#
None
2.3.5
TelNo.2(ARC2) #027 None
TelNo.3(ARC3) #028 None
TelNo.4(ARC4) #029 None
TelNo.5(PR1) #030
EnterthePersonalRecipientTelNo.
(max16digits)followedby#
None
TelNo.6(PR2) #031 None
TelNo.7(PR3) #032 None
TelNo.8(PR4) #033 None
ActivityMonitoring
Enable/Disable #034 0#=Disableor1#=Enable Disabled
2.3.6
12or24HourPeriod
andThresholdCount
#035
1
st
digit:0=12Hr
&
1=24Hr
2
nd
digit:=threshold(0to9)then#
12Hour
Threshold1
PeriodicTest
Interval(0199days)
Enable/Disable
+0Hoursor+12Hours
#036
1
st
2digits=intervalindays
3
rd
digit:0=Disable1=Enable
4
th
digit:0=+0Hrs1=+12Hrsthen#
Disabled
2.3.7
DialoutRoutine
DialSequence #037
Enterthetelephonenumberdial
sequencefollowedby#(8digits)
None
2.3.8
DialAttempts(1to9) #038
Enterthenumberofdialattemptsat
eachtelnumberfollowedby#
4
SafeCallDeviceOption #039 0#=Disableor1#=Enable Disabled
CallerPartyDisconnect #048 0#=Disableor1#=Enable Disabled
RadioDevices
ManualLearnRadioDevice #040
Enter8digitID,followedby2digit
locationcode,followedby#
N/A
2.3.9
ManualDeleteRadioDevice #041 Enter8digitIDfollowedby# N/A
AutoLearnRadioDeviceand
assignaLocationCode
#050
Activatedevice,enter2digitlocation
code,followedby#
N/A
PersonalRecipient
Message
RecordIDMessage #060 RecordPRMessage(8secsmax) N/A
2.3.10
PlayIDMessage #061 ListentoPRMessage N/A
DeleteIDMessage #062 Press#toDelete N/A
IntruderMode
Enable/Disable #063 0#=Disableor1#=Enable Disabled
2.3.11
PushbuttonSettings
RedEmergencyButton #064 0#=Disableor1#=Enable Enabled
2.3.12
YellowFunctionButton #065 0#=Disableor1#=Enable Enabled
GreenCancelButton #066 0#=Disableor1#=Enable Enabled
LEDSettings
RedEmergencyButtonLED #067 0#=Disableor1#=Enable Enabled
2.3.13
TriColourStatusLED #068 0#=Disableor1#=Enable Enabled
YellowFunctionButtonLED #069 0#=Disableor1#=Enable Disabled
GreenCancelButtonLED #070 0#=Disableor1#=Enable Disabled
SecurityCode
ChangeSecurityCode #125 Enternew4digitcodefollowedby# 1670
2.3.14