System Diagnosis Guide
Figure 18: Parameter Details Display
Parameter List (factory settings)
Parameter Description 5 PANS
115V
5 PANS
230V
Self
Contained
230v
Trolley
ADR serial address
[num]
1 1 1 1
EVO alarm intervention
super-parameter
[num]
0 0 0 0
IS1 probes and door
input conguration
super-parameter
[num]
155 155 155 155
IS2 digital input
conguration
super-parameter
[num]
8 8 8 8
IS3 not used 0 0 0 0
OS1 additional output
super-parameter
[num]
0 0 0 0
OS2 additional output
super-parameter
[num]
0 0 0 0
FOP fans mode super-
parameter [num]
131 131 131 135
DOP defrost mode
super-parameter
[num]
7 7 7 5
ALH upper temperature
alarm limit [°C/°F]
50 50 50 50
ALL lower temperature
alarm limit [°C/°F]
14 14 14 14
ALD temperature alarm
delay [min]
60 60 60 60
ADS temperature alarm
delay after start
[min]
180 180 180 180
ADF temperature alarm
delay after defrost
[min]
120 120 120 120
HYH upper dierential
cooling action
[°C/°F]
4 4 4 4
HYL lower dierential
cooling action
[°C/°F]
0
0 0 0
MNT number of trays of
blast chiller [num]
15 15 15 15
Parameter Description 5 PANS
115V
5 PANS
230V
Self
Contained
230v
Trolley
DAC compressor stop
delay [sec]
3 3 3 3
ADL minimum time of
stop compressor
[sec]
60 60 60 60
ASS start compressor
delay at power on
[sec]
30 30 30 30
CON compressor on
time in probe
faulty [min]
5 5 5 5
COF compressor o
time in probe
faulty [min]
10 10 10 10
CPH not used 90 90 90 90
FAS evaporator fan set
point [°C/°F]
50 50 50 50
HFF dierential of fan
set point [°C/°F]
9 9 9 9
FAD delay of fan start
in evaporator
probe faulty [sec]
5 5 5 5
FSD stop evaporator
fan temperature in
defrost [°C/°F]
14 14 14 14
LBT minumum
evaporator
temperature
related to set point
[°C/°F]
50 50 50 50
EDT choking evaporator
fan temperature
range [°C/°F]
59 59 59 59
FEN minimum
evaporator fan
speed % [num]
25 25 25 25
FEX maximum
evaporator fan
speed % [num]
95 95 95 95
DOO max open door
time before door
alarm [sec]
60 60 60 60
FCE condenser fan set
point [°C/°F]
77 77 77 77
HYF upper dierential
condenser fan
action [°C/°F]
9 9 9 9
MCT max condenser
temperature
[°C/°F]
131 131 131 131
DCN dirty condenser
threshold [°C/°F]
0 0 0 0
GAS low refrigerant
amount alert
threshold [°C/°F]
0 0 0 0
DCR dierential for
restarting blast
chiller after
high condenser
temperature
[°C/°F]
18 18 18 18
RMT stop time during
high condenser
temperature [sec]
180 180 180 180