System Diagnosis Guide
Parameter Description 5 PANS
115V
5 PANS
230V
Self
Contained
230v
Trolley
PMT max high
condenser event
before high temp.
Alarm [num]
3 3 3 3
TPB time threshold for
high condenser
temp. Alarm [min]
30 30 30 30
DTE defrost ending
temp related
to evap. Probe
[°C/°F]
41 41 41 41
DRP dripping time after
defrost [sec]
60 60 60 60
DTO defrost timeout
[min]
10 10 10 10
ITD interval between
two consecutive
defrosts [hours]
8 8 8 8
DCD max on-time drain
heater [min]
8 8 8 8
SDT ice detecting
sensitivity in smart
defrost mode
[num]
0 0 0 0
SD1 rst daily defrost
[hour]
0 0 0 0
SD2 second daily
defrost [hour]
0 0 0 0
SD3 third daily defrost
[hour]
0 0 0 0
SD4 fourth daily defrost
[hour]
0 0 0 0
SPX door frame heater
set point [°C/°F]
14 14 14 14
COS average power
factor of
equipment [num]
5 5 5 5
PR1 declared power
connected to
relay1 [num]
0 0 0 0
PR2 declared power
connected to
relay2 [num]
0 0 0 0
PR3 declared power
connected to
relay3 [num]
0 0 0 0
PR4 declared power
connected to
relay4 [num]
0 0 0 0
PR5 declared power
connected to
relay5 [num]
0 0 0 0
PR6 declared power
connected to
relay6 [num]
0 0 0 0
PR7 declared power
connected to
relay7 [num]
0 0 0 0
PR8 declared power
connected to
relay8 [num]
0 0 0 0
Parameter Description 5 PANS
115V
5 PANS
230V
Self
Contained
230v
Trolley
STB number of cycles
during D test
[num]
5 5 5 5
CYC number of on7o
cycles during D
test [num]
5 5 5 5
WIN max pull down
time in winter D
test [num]
90 90 90 90
SUM max pull down
time in summer D
test [num]
120 120 120 120
ETT set point in heating
cycle during D test
[°C/°F]
59 59 59 59
SPU user set point
in storage cycle
[°C/°F]
37 37 37 37
OF1 cabinet probe
oset [num]
-0.7 -0.7 -0.7 0
OF2 evaporator probe
oset [°C/°F]
0 0 0 0
OF3 condenser probe
oset [°C/°F]
0 0 0 0
OF4 core probe point 1
oset [°C/°F]
0 0 0 0
OF5 core probe point 2
oset [°C/°F]
0 0 0 0
OF6 core probe point 3
oset [°C/°F]
0 0 0 0
OF7 core probe point 4
oset [°C/°F]
0 0 0 0
OF8 core probe point 5
oset [°C/°F]
0 0 0 0
Parameter Description 5 PANS
115V
5 PANS
230V
Self
Contained
230V
Trolley
SLL not used -40 -40 -40 -40
SLH not used 3 3 3 3
RHU cabinet RH% set
point settable
[num]
80 80 80 80
MNS mains voltage
alarm limit [%]
20 20 20 20
MAL voltage alarm
delay [hours]
10 10 10 10
MEV max number of
voltage conditions
before voltage
alarm [num]
5 5 5 5
MBP time range in
which is performed
the mains voltage
control [hours]
1 1 1 1
RL1 relay 1 action type
[num]
1 1 1 1
RL2 relay 2 action type
[num]
13 13 13 13