Parameter Description 5 PANS
115V
5 PANS
230V
Self
Contained
230V
Trolley
RL3 relay 3 action type
[num]
17 17 17 17
RL4 relay 4 action type
[num]
13 13 13 13
RL5 relay 5 action type
[num]
0 0 0 0
RL6 relay 6 action type
[num]
11 11 11 11
RL7 relay 7 action type
[num]
10 10 10 10
RL8 relay 8 action type
[num]
1 1 1 1
SRV remaining
time before
maintenance [day]
800 800 800 800
PCA cabinet set point
in prechilling
[°C/°F]
28 28 28 28
PCF evaporator
fan speed in
prechilling [num]
10 10 10 10
PFA cabinet set point
in prefreezing
[°C/°F]
-22 -22 -22 -22
PFF evaporator
fan speed in
prefreezing [num]
10 10 10 10
DWA load tolerance on
relays [%]
20 20 20 20
STO max storage time
without hot gas
defrost [hours]
48 48 48 48
DFS dierence between
core probe and
cabinet probe to
detect core probe
inserted [°C/°F]
18 18 18 18
STE sterilization cycle
duration [sec]
300 300 300 300
PRH heating core probe
cycle duration
[sec]
60 60 60 60
VOF mains voltage
sensor oset
[num]
77 77 77 77
PTE not used 20 20 20 20
PTI not used 12 12 12 12
MRT max recharging
time of battery
[hours]
20 20 20 20
FCD max rst
recharging time of
battery [hours]
12 12 12 12
BTD max duration of
battery test [sec]
3 3 3 3
TBT consecutive
battery test
interval time [min]
5 5 5 5
NMT not used 250 250 250 250
VRS start battery
charging threshold
[V/10]
11,1 11,1 11,1 11,1
Parameter Description 5 PANS
115V
5 PANS
230V
Self
Contained
230V
Trolley
VRE end battery
charging threshold
[V/10]
11,3 11,3 11,3 11,3
VRT battery voltage at
ending charging
for max
duration [V/10]
9,8 9,8 9,8 9,8
VBR minimum battery
voltage for
disabling battery
[V/10]
8,6 8,6 8,6 8,6
VAD battery voltage
threshold to show
no battery
message [V/10]
3,3 3,3 3,3 3,3
Parameter Description 5 PANS
115V
5 PANS
230V
Self
Contained
230V
Trolley
VPD battery
voltage
threshold
to detect
presence of
battery [V/10]
5 5 5 5
TBK delay time
before safety
turn oof
battery circuit
[sec]
60 60 60 60
BOF battery
voltage oset
[V/10]
0 0 0 0
MST max air
temperature
during
thawing
[°C/°F]
50 50 50 50
OFH not used 3 3 3 3
PAT air
temperature
in pre-
thawing cycle
[°C/°F]
43 43 43 43
PFT evaporator
fan speed in
pre-thawing
cycle [%]
10 10 10 10
PAC air
temperature
in pre-soft
cooking cycle
[°C/°F]
43 43 43 43
PFC evaporator
fan speed
in pre-soft
cooking cycle
[%]
6 6 6 6
HHL lower
dierential
heating action
[°C/°F]
5 5 5 5
HHH upper
dierential
heating action
[°C/°F]
5 5 5 5
62

Other manuals for U-Line UCBF632-SS12A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the U-Line UCBF632-SS12A and is the answer not in the manual?

U-Line UCBF632-SS12A Specifications

General IconGeneral
BrandU-Line
ModelUCBF632-SS12A
CategoryFreezer
LanguageEnglish

Related product manuals