NEO-F10N-Integration manual
5 Product handling
5.1 Safety
5.1.1 ESD precautions
u-blox  chips  and  modules  contain  highly  sensitive  electronic  circuitry  and  are  electrostatic
sensitive devices (ESD). Observe precautions for handling! Failure to observe these precautions
can result in severe damage to the component!
•
Unless there is a galvanic coupling between the local GND
(that is, the work desk) and the PCB GND, then the first
point of contact when handling the PCB must always be
between the local GND and PCB GND.
•
Before mounting an antenna patch, connect ground of the
device.
•
When handling the RF pin, do not come into contact with
any charged capacitors  and  be  careful  when  contacting
materials  that  can  develop  charges  (for  example,  patch
antenna ~10 pF, coax cable ~50-80 pF/m or soldering iron).
•
To prevent electrostatic discharge through the RF input,
do not touch any exposed antenna area. If there is any risk
that such exposed antenna area is touched in a non-ESD
protected  work  area,  implement  proper  ESD  protection
measures in the design.
•
When soldering RF connectors and patch antennas to the
receiver’s RF pin, make sure to use an ESD-safe soldering
iron (tip).
5.1.2 Safety precautions
The NEO-F10N modules must be supplied by an external limited power source in compliance with
the  clause  2.5  of  the  standard  IEC  60950-1.  In  addition  to  external  limited  power  source,  only
Separated or Safety Extra-Low Voltage (SELV) circuits are to be connected to the module including
interfaces and antennas.
For more information about SELV circuits see section 2.2 in Safety standard IEC 60950-1.
UBXDOC-963802114-12193 - R02
5 Product handling Page 28 of 42