3
GENERAL SPECIFICATIONS
IMPORTANT SAFETY WARNINGS
Read entire Safety Notes section regarding potential hazard and proper instructions before using this analyzer. In this manual the
word “WARNING” is used to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used to
indicate conditions or actions that may damage this instrument. This analyzer must only be used in well-ventilated locations by trained
and competent persons after due consideration of all potential hazards.
To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in
severe injury or death.
• Do not use this analyzer during electrical storms or in wet weather.
• To avoid false readings, charge batteries if a low battery indicator appears.
• Always adhere to national and local safety codes. Use proper personal protective equipment (PPE).
This analyzer extracts combustion gases that may be toxic in relatively low concentrations. These gases are exhausted from the
back of the analyzer.
This analyzer is designed for trade professionals who are familiar with the hazards of their trade. Observe all recommended safety
procedures that include proper lockout utilization and use of personal protective equipment that includes safety glasses, gloves and
flame resistant clothing.
Users of portable gas detectors are recommended to conduct a “bump” check before relying on the unit to verify an atmosphere is free
from hazard. A ‘bump” test is a means of verifying that an instrument is working within acceptable limits by briefly exposing to a known
gas mixture formulated to change the output of all the sensors present. This is different from a calibration where the instrument is also
exposed to a known gas mixture but is allowed to settle to a steady figure and the reading adjusted to the stated gas concentration of
the test gas.
SYMBOLS
Low battery Degrees Fahrenheit
Degrees Celsius Pump Status
Pump Start Pump Stop
Hold Printing
Navigate Down Navigate Up
Enter Key Save Log
Operating Temperature: 32˚ to 113˚F (0˚ to 45˚C)
Storage Temperature: 0˚ to 113˚F (-18˚ to 50˚C)
Operating Humidity: 15% to 90% R.H.
Back light: Yes
Dimensions: 8.54 x 4.18 x 1.86 inch
Item Weight: 1.51 lb
Calibration: Recommended Annually
Certification: CE Conformity, RoHS, REACH Compliant,
AHRI 1260 standard
Battery Type: NiMH (AA) 3
Accuracy: ± (% of reading + # of least significant digits)