Accuracy Specifications (4)
F. DC Current
Remark:
l 4A & 10A Range:
For continuous measurement
10 seconds and
interval time between 2 measurements greater than
15 minutes.
G. AC Current
Range
Accuracy
400 A 0.1 A
4000 A 1 A
(1%+2)
40mA 0.01mA
400m
A
0.1mA
(1.2%+3)
4A 0.001A
10A 0.01A
(1.5%+5)
Resolution
Range Resolutio Accuracy
400 A
A
4000
A
1 A
40mA
400mA 0.1mA
4A 0.001A
10A
0.01A
0.1
0.01mA
(1.5%+5)
(2%+5)
(2.5%+5)
Protection
Overload
10A, 250V,
fast type Glass
fuse, 5x20mm
Remarks:
l Frequency response 40Hz ~ 400Hz.
l Displays effective value of sine wave (mean value
l 4A & 10A Range:
For continuous measurement
10 seconds and
interval time between 2 measurements greater than
15 minutes.
response).
Overload
Protection
0.5A, 250V,
fast type Glass
fuse, 5x20mm
0.5A, 250V,
fast type Glass
fuse, 5x20mm
10A, 250V,
fast type Glass
fuse, 5x20mm
Model UT60A: OPERATING MANUAL
36

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT60A and is the answer not in the manual?

UNI-T UT60A Specifications

General IconGeneral
Data holdYes
Product typeDigital multimeter
Frequency range0.01 - 10000 kHz
AC current range0.4 - 10 A
AC voltage range4 - 750 V
DC voltage range0.4 - 1000 V
Dimensions (WxDxH)85 x 177 x 40 mm
Battery voltage9 V
Weight and Dimensions IconWeight and Dimensions
Weight340 g