UTD2000 Series User Manual 
30 
 
The DSO generates a trigger when the slew rate of rising edge of signal is 
lower than the specified slew rate. 
The DSO generates a trigger when the slew rate of rising edge of signal is 
higher than the specified lower-limit slew rate  and lower than the specified 
upper-limit slew rate. 
The DSO generates a trigger when the slew rate of descending edge of signal 
is higher than the specified slew rate. 
The DSO generates a trigger when the slew rate of descending edge of signal 
is lower than the specified slew rate. 
The DSO generates a trigger when the slew rate of descending edge of signal 
is higher than the specified lower-limit slew rate and lower than the specified 
upper-limit slew rate. 
The slope time is set at 20ns~10s, adjust the time through the multifunctional 
knob on front panel. 
Adjust high-level threshold of slope trigger through the LEVEL knob on trigger 
control area. 
Adjust low-level threshold of slope trigger through the LEVEL knob on trigger 
control area. 
Through the LEVEL knob on trigger control area, adjust high-level & lowl-level 
threshold of slope trigger at the same time. 
 
 
 
4.4 Video trigger 
After the video trigger is selected, the DSO generates a trigger on the field or line of NTSC 
or PAL standard video signal. Trigger coupling will be preset to DC coupling. Video trigger 
menus are shown in the table below:   
Tabel 4-6 Video trigger menu 
Set CH1 as the triggering signal source 
Set CH2 as the triggering signal source 
 
Table 4-6 Video setting menu 
Applicable to PAL video signal.