Steam settings
(level 1, 2, 3)
Allow you to set the pressure of steam boiler.
Steam Air & hot air settings
(level 1, 2, 3)
Allow you to set the Steam air or hot water control box settings:
• the temperature at the level of the thermostatic probe of the milk (only for a machine with Steam Air)
• the steam time-delay
• the volumes of hot water
Spot pressure of the
steam boiler.
Touch the + and – keys to set the desired value.
Setting range: 0.7 Bar to 1.4 Bar, default setting 1 Bar
9 Do not forget to confirm the setting in order to save the
parameters.
9 When you select a line to make a setting, the color of
the value turns pink.
9 Touch the + and – keys to set the desired value.
9 Do not forget to confirm the setting in order to save the
parameters.
Setting range:
• Steam Air probe: 50°C to 90°C , default setting 62°C
• Steam time: 0 sec to 99 sec, default setting 10 sec
• Small water volume: 0 to 2000 ml , default setting 150 ml