8
To activate the antifreeze function only, po-
sition the two knobs as shown in the gure.
The Antifreeze protection is always active.
Even by disabling the heating and domestic hot
water services.
MAX
M
I
N
MAX
MIN
ATTENTION (*) see general warn-
ings 1.1
The heating only models are NOT
suitable for the production of water
for human consumption according
to Ministerial Decree D.M. 174/2004.
ATTENTION!
ANY DAMAGE TO THE BOILER
CAUSED BY THE FORMATION OF
FOULING OR BY CORROSIVE WATER
WILL NOT BE COVERED BY THE
WARRANTY.
1.8 - BOILER ANTIFREEZE
PROTECTION
P
O
S
ANTIFREEZE FUNCTION
Power supplies Hb (*) Status
function
antifreeze
Actions
Electric Gas
1
ON ON < 6 °C ON - Burner and Pump ON until T > 14°C
2
ON OFF
< 2 °C ON
Only when both the power supplies are ON:
- Burner and Pump OFF until T > 5°C
- When T > 5°C then Burner and Pump
ON until T > 14°C.
OFF ON
OFF OFF
(*) Sensor 11 par. 2.2
1.7 - WATER TREATMENT
The treatment of the supply water
allows to prevent inconveniences
and maintain the functionality and
efciency of the generator over time.
The ideal water pH in heating systems
must be within:
To minimise corrosion, it is crucial to
use a corrosion inhibitor; in order for
it to work properly, the metal surfac-
es must be clean.
(see system protection ACCESSO-
RIES sect. in domestic price list)
This protection can intervene only if
the electricity and gas supplies are
connected.
If one of the two is not available and
upon reset
11 (SR) a temperature of < 2
°C is detected, the appliance will behave
as described in tab. pos 2.
The heating system can be protected
effectively from frost by using antifreeze
products with inhibitor for heating
systems (specic for multidmetal)
Do not use car engine antifreeze
products as they could damage the
water gaskets.
VALUE MIN MAX
PH 6.5 8
Hardness [°fr] 9 15
NOTE!
Further details in the section
‘Technical Information’’ on the boiler
page of the www.unicalag.it website

Table of Contents

Other manuals for Unical KON R 18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unical KON R 18 and is the answer not in the manual?

Unical KON R 18 Specifications

General IconGeneral
BrandUnical
ModelKON R 18
CategoryBoiler
LanguageEnglish

Related product manuals