30
ATTENTION!
Function reserved for Authorised As-
sistance Centres only.
Some service parameters can be edited
from the control panel:
4.2 - PARAMETERS THAT CAN BE EDITED FROM THE CONTROL PANEL
OK
OK
1 ACTIVATION
By pressing the button (D) for 10 seconds, the
function is activated when the key ashes on the
display
NIGHT REDUCTION
VALUES
FROM TO TO
DEFAULT
0 (TA -0°) 5 (TA -5°) 30 (TA -30°) 0 (TA -0°)
MAXIMUM HEATING OUTPUT
VALUES
FROM TO DEFAULT
0 (Min) 99 (Max) 99
PREHEATING
VALUES
FROM TO DEFAULT
0 1 0
EXTERNAL PROBE TEMPERATURE
VALUES
FROM TO DEFAULT
0 (- 20°C) 30 (+ 10°C) 20 (0°C)
PUMP POST CIRCULATION
VALUES
FROM TO DEFAULT
0 (5 min) 1 (ALWAYS) 0 (5 min)
SELECTION
Turn the HEATING knob ‘’B’’
EDITING THE VALUE
Turn the DOMESTIC HOT WATER knob ‘’C’’
The value ashes on the display
CONFIRM SELECTION
Conrm the parameter to be edited by pressing
the unblock key
CONFIRM VALUE
Conrm the value by pressing the unblock key
PARAMETER SELECTION
Go back to section 2.
2
4
3
5
6

Table of Contents

Other manuals for Unical KON R 18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unical KON R 18 and is the answer not in the manual?

Unical KON R 18 Specifications

General IconGeneral
BrandUnical
ModelKON R 18
CategoryBoiler
LanguageEnglish

Related product manuals