30
ATTENTION!
Function reserved for Authorised As-
sistance Centres only.
Some service parameters can be edited
from the control panel:
4.2 - PARAMETERS THAT CAN BE EDITED FROM THE CONTROL PANEL
1 ACTIVATION
By pressing the button (D) for 10 seconds, the
function is activated when the key ashes on the
display
NIGHT REDUCTION
VALUES
FROM TO TO
DEFAULT
0 (TA -0°) 5 (TA -5°) 30 (TA -30°) 0 (TA -0°)
MAXIMUM HEATING OUTPUT
VALUES
FROM TO DEFAULT
0 (Min) 99 (Max) 99
PREHEATING
VALUES
FROM TO DEFAULT
0 1 0
EXTERNAL PROBE TEMPERATURE
VALUES
FROM TO DEFAULT
0 (- 20°C) 30 (+ 10°C) 20 (0°C)
PUMP POST CIRCULATION
VALUES
FROM TO DEFAULT
0 (5 min) 1 (ALWAYS) 0 (5 min)
SELECTION
Turn the HEATING knob ‘’B’’
EDITING THE VALUE
Turn the DOMESTIC HOT WATER knob ‘’C’’
The value ashes on the display
CONFIRM SELECTION
Conrm the parameter to be edited by pressing
the unblock key
CONFIRM VALUE
Conrm the value by pressing the unblock key
PARAMETER SELECTION
Go back to section 2.