13
Technical Features
ENGLISH
2.5 - GENERAL FEATURES
2.4 - OPERATING DATA ACCORDING TO UNI 10348
For the adjustment data: NOZZLES - PRESSURE - DIAGRAMS - FLOW RATES - CONSUMPTION refer to the par-
agraph ADAPTATION TO OTHER TYPES OF GAS.
KON R18/C18 R24/C24 R28/C28 R35/C35
Maximum heating thermal output (DHW) kW 18.0 (23.4) 23.4 (23.4) 28.0 (28.0) 33.0 (33.0)
Minimum heat output (propane) kW 3.0 (4.4) 3.0 (4.4) 4.4 (5.6) 4.4 (5.6)
Effective nominal output kW 17.4 22.6 27.2 32.0
Minimum effective output kW 2.9 2.9 4.3 4.3
Effective efciency at nominal load (100%) % 96.9 96.5 97.2 97.0
Effective efciency required (100%) % 95.5 95.7 95.9 96.0
Effective efciency at 30% load % 101.3 100.1 101.0 101.0
Effective efciency required (30%) % 92.7 93.1 93.3 93.5
Number of stars (according to 92/42 EEC) no.
Effective nominal output in condensation 50/30 kW 18.4 23.6 28.9 33.8
Minimum effective output in condensation 50/30 kW 3.2 3.2 4.7 4.7
Effective output with nominal load in cond. 50/30 % 102.3 100.9 103.1 102.3
Effective output with minimum load in cond. 50/30 % 107.0 107.2 106.2 106.2
Combustion efciencywithnominalload(100%) % 97.6 97.2 97.6 97.2
Combustion efciency with reduced load % 98.6 98.6 98.1 98.1
Heat loss at casing (min.-max.) % 2.0 - 0.74 2.0 - 0.7 1.47 - 0.43 1.47 - 0.2
(*) Flue gas temperature tf-ta (max.) °C 49 57.6 48 57
Flue gas mass ow rate (min.-max) g/s 1.3 - 7.9 1.3 - 10.3 2.0 - 12.5 2.0 - 14.7
Excess λ air % 20.6 20.6 23.0 23.0
CO
2
% 9.5 - 9.5 9.5 - 9.5 9.3 - 9.3 9.3 - 9.3
CO
at 0% of O
2
(min./max)
ppm 20 - 95 20 - 121 19 - 100 19 - 120
Maximum production of condensation kg/h 2.9 3.7 4.5 5.3
NOx(WeightedvalueaccordingtoEN297/A3orEN483) mg/kWh 35 39 39 43
NOx Class 5 5 5 5
Heat loss at chimneywithburneron(min.-max.) % 1.4 - 2.4 1.4 - 2.8 1.9 - 2.4 1.9 - 2.8
Heat loss at chimney with burner off % 0.60 0.46 0.41 0.34
Notes: (*) Room Temperature = 20°C Data detected with appliance running on Methane gas (G20)
KON
R18 C 18 R24 C 24 R28 C 28 R35 C35
Appliance category
II
2H3P
II
2H3P
II
2H3P
II
2H3P
Minimum heat. circuit output (∆t 35 °C) l/min
1.2 1.2 1.7 1.7
Minimum heating circuit pressure bar
0.5 0.5 0.5 0.5
Maximum heating circuit pressure bar
3 3 3 3
Primary circuit content l
2.2 2.2 2.8 2.8
Maximum operating temperature in heat. °C
85 85 85 85
Minimum operating temperature in heat. °C
30 30 30 30
Expansion vessel total capacity l
8 8 8 8
Expansion vessel pre-load bar
1 1 1 1
Maximum system capacity (maxtemp.calc.) l
184 184 184 184
Minimum domestic hot water circuit ow rate l/min.
- 2.0 - 2.0 - 2.0 - 2.0
Minimum domestic hot water circuit pressure bar
- 0.5 - 0.5 - 0.5 - 0.5
Maximum domestic hot water circuit pressure bar
- 6 - 6 - 6 - 6
Domestic hot water specic ow rate (∆t 30 °C) l/min.
- 11.2 - 11.2 - 13 - 16
Domestic hot water ow rate limiter l/min.
- 10 - 10 - 12 - 15
Production of D.H.W. in continuous operation with ∆t 45 K
l/min.
- 7.34 - 7.34 - 8.6 - 10.1
Production of D.H.W. in continuous operation with ∆t 40 K
l/min.
- 8.26 - 8.26 - 9.7 - 11.4
Production of D.H.W. in continuous operation with ∆t 35 K
l/min.
- 9.44 - 9.44 - 11.1 - 13.0
Production of D.H.W. in continuous operation with ∆t 30 K
l/min.
- 11.0 - 11.0 - 12.9 - 15.2
Production of D.H.W. in continuous operation with ∆t 25 K (*)
l/min.
- 13.2 - 13.2 - 15.5 - 18.3
Temperature adjustable in domestic hot water mode °C
-
38-60
-
38-60
- 38-60 - 38-60
Voltage/Frequency electric power supply V-Hz
230/50 230/50 230/50 230/50
Fuse on the power supply A (F)
4 4 2 2
Maximum absorbed output W
132 132 132 132
Protection rating IP
X5D X5D X5D X5D
Net weight kg
32.5 34 32.5 34 35 36.5 35 36.5
Gross weight kg
35.5 37 35.5 37 38 39.5 38 39.5
(*) mixed