3.7 Interleaved 2 of 5
3.7.1 Enable/Disable Interleaved 2 of 5
3.7.2 Set Length Range for Interleaved 2 of 5
The length of Interleaved 2 of 5 can be set to the maximum value or minimum
value. The value between the maximum and the minimum is valid.
Interleaved 2 of 5 max length command: 020404. The parameter of this command
can be set from min to 80.
Interleaved 2 of 5 min length command: 020403. The parameter of this command
can be set from 2 to max.
Example: Set the Barcode length of the minimum value 10, and the maximum
value 25:
1. Scan the Set the Maximum Length barcode.
2. Scan the numeric barcodes ”2” and ”5” in Appendix A
3. Scan the Set the Minimum Length barcode.
4. Scan the numeric barcodes”1”and”0”in Appendix A.