WARNING
All personnel shall carefully read, understand and follow all safety rules,
operating instructions, and the Scaffold Industry Association’s
MANUAL OF RESPONSIBILITIES of ANSI A92.6-1999 before performing
maintenance on or operating any UpRight Aerial Work Platform.
Operator Manual
LX31/41/50
SERIAL NO. 4022 to Current
067903-004R1

Other manuals for Upright LX31

Questions and Answers

  • P
    patrick29Aug 12, 2025
    What to do if Upright Lifting Systems charger overheats?
    • M
      Megan CookAug 12, 2025
      If the Upright Lifting Systems charger overheats, move the machine to a cooler area. Allow the machine to cool before connecting to the AC source.
  • S
    Sean CurtisAug 16, 2025
    What to do if Upright Lifting Systems has AC power problem?
    • J
      John LewisAug 16, 2025
      If there is an AC power problem with your Upright Lifting Systems, the AC outlet, extension cord, or plug might be faulty, or the AC wire could be broken. Check and repair these components as necessary.
  • R
    Richard ElliottAug 20, 2025
    What to do if Upright Lifting Systems charger has been plugged into an AC outlet with different voltage than the AC switch setting on the charger?
    • A
      Angela GarciaAug 20, 2025
      If the Upright Lifting Systems charger has been plugged into an AC outlet with a different voltage than the AC switch setting: For 063944-001 ONLY, check the fuse inside the switch box and replace it if necessary. If the fuse is good, the charger has likely failed. For all other models, check the AC main circuit breaker and reset it if needed. Also, set the voltage selector switch to the proper voltage.
  • M
    Matthew FordAug 23, 2025
    What to do if Upright Lifting Systems has high current in DC charging?
    • K
      Kelly LopezAug 25, 2025
      If there is high current in DC charging for Upright Lifting Systems, check for shorted DC output wires.
  • M
    Mason RobertsAug 27, 2025
    What to do if Upright Lifting Systems batteries are bad?
    • D
      Daniel RamseyAug 27, 2025
      If one or more batteries are bad in your Upright Lifting Systems, check the water level and look for shorted cells. Replace any bad batteries.
  • V
    Victoria DouglasAug 30, 2025
    What to do if Upright LX31 Lifting Systems fuse visible on front of charger has failed?
    • J
      John ArroyoAug 31, 2025
      If the fuse on the front of the Upright Lifting Systems charger has failed, check for a DC output short circuit and replace the fuse.
  • R
    robertsonmichaelSep 4, 2025
    What to do if Upright LX31 Lifting Systems has DC connection problems to batteries?
    • S
      Shelly RoseSep 4, 2025
      If there are DC connection problems to the batteries in your Upright Lifting Systems, check and repair the connections as necessary, and also check the fuse.
  • V
    Vincent ColemanSep 7, 2025
    How to fix low battery voltage in Upright LX31 Lifting Systems?
    • D
      David HernandezSep 7, 2025
      If the battery voltage is below 18 Volts (too low to allow the charger to turn on) in your Upright Lifting Systems, charge the batteries to at least 24 Volts with an external charger. Then, disconnect the external charger and plug in the internal charger.

Summary

Specifications

Safety Rules

Electrocution Hazard

Warning about operating near power lines.

Tip Over Hazard

Avoid driving with elevated platform on unstable surfaces.

Collision Hazard

Reminder to check for overhead obstructions before operation.

Fall Hazard

Warning against standing or sitting on guardrails.

Introduction

General Description

Overview of the machine's main components.

Controls and Indicators

Identification of platform and chassis controls.

Pre-Operation & Safety Inspection

Daily checks before operating the machine.

Labels

Controls and Indicators

Preventative Maintenance

Daily Preventative Maintenance Check List

Checklist for daily inspection of machine components.

Engine

Coolant

Procedure for checking and adding engine coolant.

Oil

Procedure for checking and adding engine oil.

System Function Inspection

Maintenance

Hydraulic Fluid

Instructions for checking and filling hydraulic fluid.

Battery Maintenance

Safety and procedures for checking battery fluid levels.

Blocking Elevating Assembly

Operation

Switching Fuels (Dual Fuel Only)

Procedure for switching between fuels on dual fuel models.

Travel with Platform Lowered

Safe procedures for driving the machine with the platform down.

Travel with Work Platform Elevated

Steering

Raising and Lowering the Platform

Transporting Work Platform

Preparation for Shipment

Steps to secure the machine for transport.

Lifting by Crane

Guidelines for safely lifting the machine with a crane.

Driving or Winching onto a Truck or Trailer

Procedures for loading the machine onto a vehicle.

Fold Down Guardrails

Emergency Lowering

Leveling the Platform (Outrigger Equipped Machines Only)

Outrigger Switches and Indicator Lights

Explanation of outrigger controls and indicator lights.

To Level the Platform (Extend the Outriggers)

Step-by-step guide to extending outriggers for leveling.

To Retract the Outriggers

Procedure for retracting the outriggers.

Towing or Winching

Parking Brake Release

How to release the parking brake for towing.

After Use Each Day

Daily shutdown and securing procedures.