USR IOT USR-N580 - User Manual

USR IOT USR-N580
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
USR-N580 User Manual technical support:h.usriot.com
Jinan USR IOT Technology Limited
1
www.usriot.com
USR-N580 User Manual
File Version: V1.0.1
Question and Answer IconNeed help?

Do you have a question about the USR IOT USR-N580 and is the answer not in the manual?

USR IOT USR-N580 Specifications

General IconGeneral
ModelUSR-N580
Serial Ports2 x RS232/RS485
USB Ports1 x USB 2.0
Power SupplyDC
Storage Temperature-40°C ~ 85°C
Humidity5% ~ 95% (non-condensing)
Protocol SupportTCP, UDP, HTTP, DHCP, DNS

Summary

Introduction to USR-N580

Overview and Features

Explains the USR-N580 module's purpose, configuration methods, and key functions.

Getting Started with USR-N580

USR-N580 Specifications

Details technical specifications of the USR-N580 device.

USR-N580 Hardware Details

Describes physical dimensions and indicator lights of the USR-N580 device.

Connecting Hardware and Power

Guides on serial/network connections, and power supply setup for the USR-N580.

Utility Configuration Guide

Download and Start Configuration Utility

Instructions for downloading, starting, and discovering the configuration utility and device.

Network Settings Configuration

Explains configuring static or DHCP IP addresses for the device server.

Serial Port Settings

Details serial port parameters like baud rate, data bits, parity, and flow control.

Miscellaneous and Factory Settings

Covers changing module name, user credentials, and restoring factory default settings.

Update USR-N580 Firmware

Guides on updating firmware via webpage or configuration utility.

Selecting Operating Modes

Overview of Operating Modes

Introduces configuring the device port's operation mode for different network protocols.

TCP Client Mode Configuration

Explains TCP Client mode, its features like keepalive, and provides a test example.

TCP Server Mode Configuration

Details TCP Server mode, keepalive function, client connections, and a test example.

UDP Client Mode Configuration

Explains UDP Client mode, its use cases, and provides a test example.

UDP Server Mode Configuration

Describes UDP Server mode, source IP handling, and provides a test example with multiple clients.

HTTP Client Mode

Explains Httpd Client mode for sending HTTP requests and processing responses.

General Functions

Serial Packaging and Flow Control

Explains serial data packaging and flow control settings for transparent transmission.

RFC2217 Functionality

Describes the RFC2217 function for dynamic serial parameter changes over the network.

Modbus RTU to TCP Conversion

Explains the protocol conversion process from Modbus RTU to Modbus TCP.

Modbus Poll Functionality

Details how to use Modbus Poll to query parameters via multiple masters.

Heartbeat Packet Configuration

Explains serial and network heartbeat packets for connection maintenance.

Registry Packet Setup

Describes registry packets (USR Cloud, MAC, USER) for device identification and authorization.

Short Connection Feature

Explains the TCP short connection feature for saving server resources and automatic disconnection.

Uart Cache Functionality

Details the UART cache function for buffering serial data when connections are not established.

UDP Multicast Configuration

Explains UDP multicast for one-to-many connections and its address range.

Web Socket Configuration

Describes Websocket function for data transmission between serial ports and the N580 webpage.

Network Printing Function

Explains network printing using the serial port and a printer driver.

Virtual COM Software Setup

USR Cloud Platform Integration

AT Command Set Reference

Document Disclaimer

Related product manuals