7
6.2.6 Setting the time of regeneration
n Press the MENU button
n Select REGENERATION TIME using the UP/DOWN buttons
n Confirm by pressing the SET/REGEN button
n Press the SET/REGEN button, to activate selected digit
n Set the hour regeneration starts using the UP/DOWN buttons
n Confirm by pressing the SET/REGEN button
n Select minutes using the UP/DOWN buttons
n Confirm by pressing the SET/REGEN button
n Set the minutes regeneration starts using the UP/DOWN buttons
n Confirm by pressing the SET/REGEN button
n Press the MENU button
Time
Regen
n Select „METER OVERRIDE” (recommended) using the UP/DOWN buttons
n Confirm by pressing the SET/REGEN button
n Press the MENU button
6.2.7 Setting regeneration frequency (in days)
n Press the MENU button
n Select REGENERATION DAYS using the UP/DOWN buttons
n Confirm by pressing the SET/REGEN button
n Press the SET/REGEN button, to activate selected digit
n Set number of days between regenerations using the UP/DOWN
buttons
n Confirm by pressing the SET/REGEN button
n Set minutes using the UP/DOWN buttons
n Confirm by pressing the SET/REGEN button
n Press the MENU button
Regen
Days
Regen
Time
6.2.8 Setting the amount of treated water
The amount of water which can be treated, can be calculated using the following formula:
1263.8 / FEEDWATER HARDNESS (EXPRESSED WITH PPM).
People
Number
n Press the MENU button
n Select PEOPLE NUMBER by using UP/DOWN buttons
n Confirm by pressing the SET/REGEN button
n Set amount of water to be treated before regeneration, set every
following digit using the UP/DOWN buttons and confirm using
SET/REGEN buttons
n Press the MENU button