6.2.9 Setting cycles duration
n Press the MENU button
n Select REGENERATION CYCLE using the UP/DOWN buttons
n Confirm by pressing the SET/REGEN button
n Set the time of each cycles according to the values listed
below:
Data input method is the same as for setting the amount of water.
Recommended duration of each cycle is:
n backwash 1 - 06 min
n brine - 50 min
n backwash 2 - 06 min
n refill - 8 min
n Press the MENU button softener is now in automatic operation mode.
Regen
Cycle
15
6.2.10 Restoring defaults
n Press the MENU button
n Select RESTORE DEFAULTS using the UP/DOWN buttons
n Confirm by pressing the SET/REGEN button
n Press the MENU button 3 times
ATTENTION! Skip this step if the device works properly.
n Initiating this mode will delete all settings and return to the
factory defaults
Restoring
defaults
7. Start-up procedure
n Set the by-pass valve in:
n INLET OPENED, OUTLET CLOSED.
n VERY SLOWLY open the feedwater valve by ¼ turn and wait
until the tank with the resin will be filled with water.
n After filling the tank with water, open the valve to the
maximum.