1. Soeners’ technical parameters
34 dH x m
57 dH x m
71 dH x m
102 dH x m
114 dH x m
10" / 17"
8" / 35"
10" / 35"
10" / 35"
10" / 54"
32 / 50 / 67 cm
32 / 50 / 114 cm
32 / 50 / 114 cm
31 / 52 / 114 cm
65 / 38 / 177 cm
1,8kg 3kg
3,8kg
3kg 5,5kg
12l
105l
20l
220l
25l
220l
30l
220l
40l
260l
0,8 (m/h) 1,2 (m/h) 1,2 (m/h)
1,2 (m/h) 1,7 (m/h)
two-piece soener
compact
5 min
5 min
6 min
40 min
8 min
8 min
10 min
60 min
10 min
10 min
10 min
60 min
10 min
10 min
10 min
60 min
12 min
12 min
13-14 min
60 min
220-240 V / 50-0Hz, 12V (1A)
2,5 - 4 bar
5W (only during regeneration)
6 bar
1 - 30C
1"
4 - 30C
symbol
WS-25-1650-PRIMO WS-30-H-1650-MONO ST-40
back wash
rinse
refil
brine
type
nominal flow
content of ionite
general ion-exchange ability
water consumption for regeneration
at pressure 2,6 bar
average salt consumption for
regeneration
device dimensions width / depth / height
cylinder size diameter / height
power supply, voltage
power consumption
ambient temperature
nominal pressure
maximum pressure
connection
feed water temperature
2. General information
Compact soeners are certified by NHI (National Institute of Hygiene). The certificate allows the device to come into
contact with drinking water.
2.1. Power suppy. The soeners require 230 V power supply. In case of power failure the settings are stored for about
48 hrs.
2.2. Feed water quality. The soener is dedicated to treat water free from iron, manganese and ammonia compounds.
In order to ensure proper operation of the device, extend its service life and enhance the quality of water it is not
allowed to treat water which physicochemical parameters exceed applicable standards (excluding hardness).
Water soener should not be used to treat water from private well. Before treatment water should be tested for
iron, manganese and ammonia presence.
2.3. Hydraulic installation. The hydraulic system to which the soener is connected must be free from deposits. In
case of large scale and iron deposits we recomend to replace the pipes with new ones. If this is not possible we
recommend to set the output hardness at 5 dH.