TROUBLESHOOTING
Problem Possible Cause Corrective Action
Pump will not
prime or retain
prime after
operating.
1. Pump won’t prime. 1. See priming instructions on page 6.
2. Suction lift too high. 2. Move pump closer to water source.
3. Hose kinked. 3. Straighten hose.
4. Hose fitting not tight on inlet. 4. Tighten fitting.
5. Air leak in suction hose. 5. Repair or replace hose.
Pump runs
but no water is
discharged.
1. Hose kinked. 1. Straighten hose.
2. Pump is not primed. 2. See priming instructions on page 6.
3. Defective impeller. 3. Replace impeller.
4. Suction lift too high. 4. Move pump closer to water source.
5. Discharge height too great. 5. Reduce discharge height.
6. Clogged inlet. 6. Clean inlet.
Motor runs too
hot.
1. Voltage incorrect. 1. Connect to 115 volt outlet.
2. Restricted discharge hose. 2. Increase hose diameter to 3/4 in.
3. Impeller damaged. 3. Replace impeller.
4. Plugged or kinked discharge. 4. Clean and straighten hose.
5. Insufficient air flow on motor. 5. Make sure ample fresh air is available
at the motor.
Flow rate is low. 1. Hose kinked. 1. Straighten hose.
2. Clogged impeller. 2. Clear obstruction.
3. Worn impeller. 3. Replace impeller.
4. Excessive length of hose. 4. Reduce length of inlet and outlet hose.
Pump will not
run.
1. No power. 1. Verify that unit is plugged into 115 volt
outlet.
2. Impeller jammed. 2. Clean pump cavity and impeller.
3. Motor overheated. 3. Motor has automatic thermal protector.
Wait fifteen minutes for motor to cool.
WARRANTY
This product is warranted for one year from the date of purchase. Subject to the conditions hereinafter set
forth, the manufacturer will repair or replace to the original consumer, any portion of the product which proves
defective due to defective materials or workmanship. This warranty does not cover replacement parts for
failure due to normal wear and tear. To obtain warranty service, contact the dealer from whom the product
was purchased. The manufacturer retains the sole right and option to determine whether to repair or replace
defective equipment, parts or components. Damage due to conditions beyond the control of the manufacturer
is not covered by this warranty.
THIS WARRANTY WILL NOT APPLY: (a) To defects or malfunctions resulting from failure to properly install,
operate or maintain the unit in accordance with printed instructions provided; (b) to failures resulting from
abuse, accident or negligence or use of inappropriate chemicals or additives in the water; (c) to normal
maintenance services and the parts used in connection with such service; (d) to units which are not installed
in accordance with normal applicable local codes, ordinances and good trade practices; and (e) if the unit is
used for purposes other than for what it was designed and manufactured.
RETURN OF WARRANTED COMPONENTS:
9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Utilitech 50AC-110N and is the answer not in the manual?

Utilitech 50AC-110N Specifications

General IconGeneral
BrandUtilitech
Model50AC-110N
CategoryWater Pump
LanguageEnglish

Related product manuals