7.3.1
Monitoring menu (M1)
You can enter the Monitoring menu from the Main menu by pressing
Menu button right
when the
location indication
M1 is visible on the first line of the display. Figure 3-1 shows how to browse
through the monitored values.
The monitored signals carry the indication V#.# and they are listed in Table 7-1. The values are
updated once every 0.3 seconds.
This menu is meant only for signal checking. The values cannot be altered here. For changing values
of parameters, see Chapter 7.3.2.
Figure 7-4 Monitoring menu
Code
Signal name
Unit
Description
Output frequency Hz Frequency to the motor
Frequency reference Hz
Motor speed rpm Calculated motor speed
Motor current A Measured motor current
Motor torque %
Calculated actual torque/nominal torque of the
Motor power %
Calculated actual power/nominal power of the
Motor voltage V Calculated motor voltage
DC-link voltage V Measured DC-link voltage
Unit temperature ºC Heat sink temperature
Motor temperature % Calculated motor temperature
Voltage input V AI1
Current input mA AI2
DIN1, DIN2, DIN3 Digital input statuses
DIN4, DIN5, DIN6 Digital input statuses
DO1, RO1, RO2 Digital and relay output statuses
Analogue output
mA AO1
M1.17
Multimonitoring
items
Displays three selectable monitoring values. See
chapter 7.3.6.5.
Table 7-1. Monitored signals
Note! All in One applications may embody more monitoring values.