Certified air/flue systems and components 3
0020200969_07 Set-up instructions 7
3 Certified air/flue systems and components
3.1 System overview, 60/100 mm diameter
Article number Air/flue systems, concentric
0020223472 Vertical roof duct (black, RAL 9005), with collar
303982 Vertical ridge roof duct
0020228140¹ Direct, rear-side, telescopic flue system
0020219517¹ Horizontal wall duct, 0.7 m
0020219518¹ Horizontal telescopic wall duct (only available in black)
0020219519¹ Horizontal wall duct, 1.7 m
0010035512² Horizontal wall duct, 0.7 m for multi-storey buildings
1 In accordance with the construction regulation, installation in buildings higher than 18 m is not permitted.
2 In accordance with the construction regulation, installation in buildings higher than 18 m is permitted.
3.1.1 Components
The following table lists the air/flue systems that are permitted as part of the system certification, along with their certified
components.
Optional connection ac-
cessories
Article
number
0020223472 303982 0020228140 0020219517
0020219519
0020219518 0010035512
Extension (PP), concentric,
470 mm, 60/100 mm diameter
303902 X X X X X
Extension (PP), concentric,
970 mm, 60/100 mm diameter
303903 X X X X X
Extension (stainless steel),
concentric, 970 mm,
60/100 mm diameter ³
0010035514 X X
Extension (PP), concentric,
1970 mm, 60/100 mm dia-
meter
303905 X X X X X
Extension (PP), concentric,
3960 mm, 60/100 mm dia-
meter ¹
0020138174 X X X X X
45° elbow (2 pcs), concentric 303911 X X X X X
87° elbow, concentric 303910 X X X X X
Pipe clamp (5 pcs), 100 mm
diameter
303821 X X X X X
Adjustable pipe clamps (3
pcs), 100 mm diameter
303935 X X X X X
Sliding sleeve 303915 X X X X X
Pitched roof tile 009076
(black)
X
Universal pitched roof tile 303980 X
Flat roof penetration collar 009056 X
Telescopic extension, 440-
690 mm, 60/100 mm diameter
303906 X X
Telescopic offset piece 303919 X X
Black terminal set for hori-
zontal air/flue pipe
0020219537 X X
Variable terminal set (VTK),
black ²
0020219529 X X X
Variable terminal set (VTK),
white ²
0020219530 X
1 To reduce the pipe connections that need to be inspected, 4 m extensions are offered on request. (Special delivery with minimum pur-
chasing quantity. No returns accepted.) The required downward gradient is also 3°. A height of 200 mm is therefore required for the 4 m
extension. Take the height into consideration when selecting the installation site.
2 Delivery with pipe clamps
3 In accordance with the construction regulation, installation on the external wall in buildings higher than 18 m is permitted. The sleeve
end of the extension must protrude at least 60 mm from the wall to comply with fire-protection requirements.