Integer Values (x100, Metric)
1)
261 0104
hex
Absolute humidity 16-bit signed
integer
g/m
3
262 0105
hex
Mixing ratio 16-bit signed
integer
g/kg
263 0106
hex
Wet-bulb temperature 16-bit signed
integer
°C
264 0107
hex
Enthalpy 16-bit signed
integer
kJ/kg
Integer Values (x100, Non-metric)
1)
385 0180
hex
Relative humidity 16-bit signed
integer
%RH
386 0181
hex
Temperature 16-bit signed
integer
°F
387 0182
hex
Dew point temperature 16-bit signed
integer
°F
388 0183
hex
Dew/frost point
temperature
16-bit signed
integer
°F
389 0184
hex
Absolute humidity 16-bit signed
integer
gr/ft
3
390 0185
hex
Mixing ratio 16-bit signed
integer
gr/lb
391 0186
hex
Wet-bulb temperature 16-bit signed
integer
°F
392 0187
hex
Enthalpy 16-bit signed
integer
Btu/lb
1) NOTE: 16-bit integers have a maximum value of +32767. Certain measurement parameters
(for example, mixing ratio and enthalpy) can exceed this value in x100 scaling. In such cases,
the value of the parameter is cut o at +32767, and measurements above this value are not
reported. Verify that the measurement ranges in your application are suitable for the 16-bit
integer format with x100 scaling; whenever possible, it is recommended to use 32-bit float
values.