BUS BODY ELECTRONICS
15
Table 5 - Error code overview
F03
System type
No basic or standard system
recognized
Replace ECU
F04
Room tempera-
ture sensor
Short-circuit to positive
Inspect wiring harness
Replace sensor
Replace ECU
F05
Room tempera-
ture sensor
Short-circuit to ground
Inspect wiring harness
Replace sensor
Replace ECU
F06
Environmental
temperature
sensor (SC410
only)
Short-circuit to positive
Inspect wiring harness
Replace sensor
Replace ECU
F07
Environmental
temperature
sensor (SC410
only)
Short-circuit to ground
Inspect wiring harness
Replace sensor
Replace ECU
F08
EEPROM
No access to EEPROM (data
inconsistency)
Replace ECU
F09
Refrigerant va-
lve (SC410
only)
Refrigerant valve cannot be
calibrated or run to the correct
position.
Inspect wiring harness
Replace motor
Replace ECU
F10
Coupling
Repeated occurrence of
high/low pressure error
See F00 remedy