Page #17 background image
Pilot
Flame
Thermocouple
Probe must be
in Flame
Correct Flame Appearance
Servicing & Maintenance
Checking Pilot and Burner Flames
A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make
sure that dirt, snow, insects, leaves, shrubs, trees do
not obstruct it.
Examine the whole vent system regularly. We
recommend annually.