33” (838 mm)
24” (610 mm)
15”
(381 mm)
15”
(381 mm)
4”
(102 mm)
3”
(76 mm)
3”
(76 mm)
3”
(76 mm)
23” (584 mm)
to top of rebox
Gas line
access
Gas line approx. 24“ (610 mm)
of ex protruding from
sheet metal box
Optional
fan
Optional fan
6’ (1,8 m) fan
power cord
outlet
6’ (1.9 m) Fan power cord
Trim
(sold separately)
Valve
access
panel
9-1/2”
(241 mm)
AutoFire slider
assembly
X
Y
Dimensions
Cavity
Check that masonry step does not interfere with install dimensions or
vent pipe.
If mantel is combustible, see following section for allowable clearances.
A hearth that is at a height within 4” (102 mm) of the bottom of the heater
MUST be non-combustible.
all trims except 799 Edgemont Door
with 799 Edgemont
Door Kit
standard
install
w/796 level-
ing platform
w/795
fan kit
no fan w/795 fan
Width
(minimum
replace
opening
at front)
33-1/4”
(855 mm)
33-1/4”
(855 mm)
33-1/4”
(855 mm)
35-3/4”
(908 mm)
Depth X
15-1/2”
(394 mm)
16”
(406 mm)
18-1/2”
(470 mm)
16-3/4”
(426 mm)
19-3/4”
(502 mm)
Height Y
23-1/4”
(591 mm)
23-1/4”
(591 mm)
23-1/4”
(591 mm)
23-3/4”
(603 mm)
Minimum Cavity Dimensions
QUALIFIED
INSTALLER
21