EasyManuals Logo

Valor Portrait Series Installation Manual

Default Icon
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3
28” (710 mm)
24-1/2” (620 mm)
24-1/2” (620 mm)
B
A
Ceiling
36”
(914 mm)
min.
36” (914 mm)
min. to
combustibles
See table
Spacers for
combustible
walls (1-1/4” thick)
14-1/2” (368 mm)
13-1/4” (336 mm)
E
Mantel leg
- see
table
Mantel
D
25-1/2”
(648 mm)
16” (406 mm)
WALL
FLOOR
7-1/2”
(190 mm)
3-3/4” (95 mm)
from upper
fixing points to
center of rear
vent pipe
Appliance
outline
Center line
of appliance
9-7/8”
(250 mm)
Fixing
points
Dimensions & Clearances
Mantel Depth “A” Min. Clearance “B
Up to 7” 4”
Above 7” up to 8 5”
Above 8” up to 9 7”
Above 9” up to 10 8
Above 10” up to 12 9
More than 12
9” +extra 1” for every 1” depth
above 12”
Mantel Leg Projection “D
Min. Clearance from
Appliance Side “E
Up to 8” 0
More than 8” 6”
1-1/4”
(32 mm)
min. from
casting Top
to wall
Allow
more
space as
necessary
for venting
components
28” (711 mm) min.
1-1/4”
(32 mm)
min. from
casting Top
to wall
3-3/4”
(95 mm)

Other manuals for Valor Portrait Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Valor Portrait Series and is the answer not in the manual?

Valor Portrait Series Specifications

General IconGeneral
Fuel TypeNatural Gas or Propane
Glass Viewing AreaVaries by model
Safety FeaturesSafety Screen, Automatic Shut-off
DimensionsVaries by model
WeightVaries by model

Related product manuals