2.13. Troubleshooting
Table 2.1 4160 TPE sealing system troubleshooting guide
Make sure the unit is plugged in
and the power switch is turned
"ON".
Ensure the power cord is not
damaged.
Replace the fuse. Refer to Fuse
Replacement on page 26.
Heater or sensor failure.
Send to Vante for repair.
Verify the correct material is
selected.
Verify that the temperature, timing,
and cooling settings are appropriate
for the material and sealing
conditions.
Call Vante customer service for
more information.
Air supply is disconnected
Verify that the air supply tube is
connected to an appropriate source.
Uneven cooling
between heating plates
Possible obstruction in air
supply
Look for any kinks in the black air
hose leading to upper heating plate.
If the air supply is clear, contact
Vante customer service for more
instructions.