K6/K6N Vacuum Packaging Machine
Operation
2002-04-25 Art. no. 519.340 Page 35/56
9.5.4 Program overview
The procedure for compiling or changing a program is outlined in the table below. You do not have to
adhere to this order, although it is recommended for checking that the procedure is complete.
Function button Function Select settings
with the arrow buttons*
or
Select vacuuming mode
The vacuuming modes are described in the section
on the “Meaning of the parameters“.
A, B, C
Vacuuming to evaporation point A
Vacuum setpoint 400 ... 999 ‰
Evaporation sensitivity 0.5 ... 10.0 seconds
Vacuuming to setpoint B
Vacuum setpoint 400 ... 999 ‰
Vacuuming in stages to setpoint C **
Vacuum setpoint 400 ... 999
Vacuum stage 50 ... 499 ‰
Vacuum stop time 0 ... 200 seconds
Inert gas **
400 ... 999 ‰
999 ‰ = no inert gas
Intermediate ventilation 0.0 ... 1.0 second(s)
Welding 0.0 ... 5.0 second(s)
Cutting 0.0 ... 5.0 second(s)
Preventilation (Soft air) 400 ... 999 ‰
999 ‰ = no preventilation
Return to the basic setting
Is possible from any function.
* Arrow keys, see previous section on ”Compiling or changing a program “, field D.
** Can be switched on and off in the service program.