Why is the compressed air supply too low in my vc999 K7?
L
Laura JordanAug 5, 2025
The compressed air supply might be low due to several reasons:
* The compressed air might not be connected. Ensure it is properly connected.
* The main valve on the mains could be closed. Open the main valve.
* There might be a leak in the compressed air supply line. Check the supply line for leaks and fix them.
* The setting on the FRL unit might be too low. Check that the setting is approximately 5 bar.
* The pressure switch might be faulty. Inspect the pressure switch.
S
Sean LivingstonAug 15, 2025
What to do if there is an error with the frequency converter conveyor belt in my VC999 Kitchen Appliances?
J
Jennifer RoweAug 15, 2025
An error with the frequency converter conveyor belt may occur if:
* The current value setting on the frequency converter is too low. Check the setting in the frequency converter.
* The conveyor belt is strained. Check the transport area.
P
Patrick WilliamsAug 26, 2025
Why is the hand safety-guard monitoring actuated on my VC999 Kitchen Appliances?
M
marshalljohnAug 26, 2025
The hand safety-guard monitoring might be activated because of resistance of the lid on closure. Remove any foreign matter from the sealing area.