Vacuum Packaging Machine VC999 K7
Maintenance
2008-11-26 Art.-No. 592.016 Page 89/121
11.3 Maintenance vacuum pump(s)
NOTICE
Maintenance work at the pump must be carried out by an authorized and fully qualified techni-
cian.
CAUTION
Make sure that the machine is switched off and completely disconnected from the electrical
power supply and compressed air supply prior to carrying out maintenance!
Carry out all maintenance work at the vacuum pump according to the instructions in the separate user
manual of the pump manufacturer. This user manual can be found under the "Vacuum pump" index tab.
Recommended oil types
Recommended oil products Manufacturer
Indol 100 VC999 spez. Panolin
Indol ISO 100 Panolin
Teresso 100 ESSO
Corena H 100 Shell
Energol RC 100 BP
NOTICE
Synthetic oils must not be mixed with one another or with mineral oils. Always use the same
type of oil when refilling!
NOTICE
Dispose of used oil in accordance with regulations and in an environmentally friendly way.
11.4 Tensioning the conveyor belt
If the tension is correct, the conveyor belt should run centrally. If you find that the belt is running to one
side, you will need to adjust the belt tension with the adjusting screws located on the front in the con-
veyor belt panel.
Let the belt run and move the deflection roller on the side outwards where the belt projects sideways.