Vacuum Packaging Machine VC999 K7
Operation
Page 64/121 Art.-No. 592.016 2008-11-26
Parameter Function
Possible
settings
Factory
settings
Conveyor belt posi-
tioning time
If the position sensor of the conveyor belt is
defective, the defect mode can be activated
here. The conveyor belt is then positioned in
a time-based manner. The positioning time
appears once the defect mode has been
activated.
0,5 - 10,0 s -
NOTICE
Observe the note on danger for the parameter "Sensor for sealing bar position"!
9.8.3 Mask 156: Service parameter
Access this mask after entering the step 3 password.
The parameters listed here are so-called initial settings.
Press an input field to change the corresponding setting.
The individual functions and effects are described below.
Fig. 9/25
Explanation of the parameters
Parameter Function
Possible
settings
Factory
setting
Central vacuum Switch on this function if the Vacuum Packag-
ing Machine is to be connected to a centrally
controlled vacuuming system.
on
off
off
Intermediate
ventilation
The function "Intermediate ventilation" is ex-
plained in the description of the Mask
101/102: Parameter 1/2 under "Explanation of
the parameters".
on
off
off
Shot packaging
cycle
In position "on", the packaging cycle is accel-
erated by approx. 1 - 2 seconds. As a result,
the conveyor belt is, for example, started
shortly after opening the vacuum chamber.
Please read the NOTICE at the bottom of this
table!
on
off
off