Vacuum Packaging Machine VC999 K7
Operation
Page 48/121 Art.-No. 592.016 2008-11-26
9.5.3 Mask 11: Counter
This mask contains:
• Operating hours counter
• Cycle counter
• Pre-selection counter
The counters can be reset according to the following ta-
ble.
Fig. 9/11
Counter Resettable in step
Operating hours since last oil change 4, only by VC999 service engineer
Operating hours since last oil service 4, only by VC999 service engineer
Cycles since sealing bar check 4, only by VC999 service engineer
Actual value counter cycles/day 2
Set point pre-selection counter 2
Actual value pre-selection counter 2
9.5.4 Mask 12: Graph
Press Manual sealing to warm up the sealing bars. The
temperature profile at the sealing bars is graphically dis-
played on the screen.
The temperature profile relates to the sealing bars
switched on in Mask 102: Parameter 2/2 under "Seal-
ing".
Function:
The sealing bars are heated up to the set point for 1
second. The heat up and cool down process can be mo-
nitored on the displayed graph.
Fig. 9/12