Fig. 11: Installation with vessel vibrations
1 Anti vibration blocks or rubber buffers
2 Window of non-conductive material, for example, glass, plastic, etc.
Angle
For an optimum switching signal, the two sensors must be adapted to
each other. The accuracy must be in a range of ±5°.
Offset
The two sensors can have an offset of up to < 5 % of the sensor
distance (d) to each other. Example: with a sensor distance of
1000 mm, the two sensors must have an offset of max. 50 mm to each
other.
General rule: the bigger the antenna and the better it focusses, the
more precise the orientation has to be.
Fig. 12: Orientation of the sensors - Angle and offset
Orientation of the sensor
20 VEGAMIP R61 • - Transistor
4 Mounting
40694-EN-120228