EasyManua.ls Logo

Vega VEGAMIP R61 - Sensor Orientation

Vega VEGAMIP R61
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
2
Fig. 11: Installation with vessel vibrations
1 Anti vibration blocks or rubber buers
2 Window of non-conductive material, for example, glass, plastic, etc.
Angle
For an optimum switching signal, the two sensors must be adapted to
each other. The accuracy must be in a range of ±5°.
Oset
The two sensors can have an oset of up to < 5 % of the sensor
distance (d) to each other. Example: with a sensor distance of
1000 mm, the two sensors must have an oset of max. 50 mm to each
other.
General rule: the bigger the antenna and the better it focusses, the
more precise the orientation has to be.
+
-
d
<
d
20
Fig. 12: Orientation of the sensors - Angle and oset
Orientation of the sensor
20 VEGAMIP R61 - Transistor