4
1 For your safety
VEGAPULS 67 • HART and accumulator pack
47154-EN-210621
with intended use. The band range of the measuring frequency can
be found in chapter " Technical data".
1.5 EU conformity
ThedevicefullsthelegalrequirementsoftheapplicableEUdirec-
tives.ByaxingtheCEmarking,weconrmtheconformityofthe
instrument with these directives.
The EU conformity declaration can be found on our homepage.
1.6 NAMUR recommendations
NAMUR is the automation technology user association in the process
industry in Germany. The published NAMUR recommendations are
acceptedasthestandardineldinstrumentation.
ThedevicefullstherequirementsofthefollowingNAMURrecom-
mendations:
•
NE 21 – Electromagnetic compatibility of equipment
•
NE 43 – Signal level for fault information from measuring transduc-
ers
•
NE53–Compatibilityofelddevicesanddisplay/adjustment
components
•
NE107–Self-monitoringanddiagnosisofelddevices
For further information see www.namur.de.
1.7 Radio license for Europe
The instrument was tested according to the latest issue of the follow-
ingharmonizedstandards:
•
EN 302372 - Tank Level Probing Radar
It is hence approved for use inside closed vessels in countries of the
EU.
UseisalsoapprovedinEFTAcountries,providedtherespective
standards have been implemented.
Foroperationinsideofclosedvessels,pointsatofinannexEof
EN302372mustbefullled.
1.8 Radio license for USA
ThisapprovalisonlyvalidforUSA.Hencethefollowingtextisonly
available in the English language.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
•
Thisdevicemaynotcauseinterference,and
•
Thisdevicemustacceptanyinterference,includinginterference
that may cause undesired operation of the device
Thisdeviceisapprovedforunrestricteduseonlyinsideclosed,sta-
tionaryvesselsmadeofmetal,reinforcedberglassorconcrete.
Changesormodicationsnotexpresslyapprovedbythemanufac-
turer could void the user’s authority to operate this equipment.