19
4- Measuring device
5- Location of the measuring device
If you have selected NO
Select CURVE or Meter, depending
on what you have installed.
House circuit
Select House circuit when the
measuring device is located in a
circuit that only measures home
consumption, but not that of the
charger.
General circuit
Select General circuit when the
measuring device is located in
a circuit that measures total
consumption of both your home and
the charger.
4- Measuring device
If you have selected YES
The default setting is the Meter
option.
The default setting is the General
circuit option.
Select one of the two integration
alternatives:
Mixed mode
The energy for the charge comes both
from solar generation and from the
grid.
The charge can be programmed:
• At the programmed time, the charger
adjusts the vehicle charge power
to prevent it from exceeding the
contracted power.
• Outside the programmed time, the
charger adjusts the vehicle charge
power to prevent spillage (Solar Mode).
Solar Mode
The charge power is exclusively solar
generated. The charger adjusts the
vehicle charge power to prevent
spillage into the electricity grid.
Choosing this option means that the
charge cannot be programmed.
5- Location of the measuring device
6- Mode
7. MANAGING THE CHARGER
FROM THE VELTIUM APP