Instructions for programming SVE01 Board
functions
23
© SandenVendo Europe SpA
02 Custom Cyrillic It is the language inserted on the USB key, in the desired language with
Cyrillic characters
Note: To reset the default language (English) press the programming button on the SVE01
board while turning on the machine, and then confirm by pressing button on the
external keyboard.
4.10.3 ~ 03 Cooling
4.10.3.1 ~ 00 Temperature display
Within this submenu you can enable or disable the display of the temperature in
vend mode.
4.10.3.2 ~ 01 HACCP Enable
Within this submenu you can enable or disable the function of HACCP which make
it appear the menu "02 HACCP Parameter"
4.10.3.3 ~ 02 HACCP Parameter
Menu which are visible only when HACCP is enabled.
This function refers to the HACCP regulations to ensure the food products safety
sold through the Vending machines.
HACCP standard uses 3 parameters for determining the INHIBIT SELECTION
(SALES) of the products (all can be programmed through HACCP parameter) .
(1) : Temperature threshold.
(2) : Time (duration) of temperature excess.
(3) : Maximum Temperature threshold.
The first 2 parameters are related to each other, because when the machine detects
the temperature exceeds the set threshold temperature (1), it controls (via the
parameter (2): Time of temperature excess) for how long it stayed above the set
value (1). If the temperature stayed above set value (1) for a longer than the value
set for (2) the vending machine inhibits the selections which were programmed
with HACCP parameters (see below parameter 03 HACCP Products).
The maximum temperature threshold directly inhibits the selections which are
programmed with HACCP parameters if the set value (3) is exceeded.
When the selection related to HACCP parameters are inhibited next to the date and
time appears an asterisk (*) to indicate the error of the HACCP. You can view and
reset the error in the appropriate menu "00 Historical Error".
4
11.3 Tecnician Menu
02 Language
03 Cooling
04 SVE01 Update
11 General Menu
10 Test
11 Technician menu
12 EVA Counters

Other manuals for Vendo SVE DV6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vendo SVE DV6 and is the answer not in the manual?

Vendo SVE DV6 Specifications

General IconGeneral
BrandVendo
ModelSVE DV6
CategoryVending machines
LanguageEnglish

Related product manuals