74
Operating Instructions
1. Before using your furnace, it is suggested to open entrance door
and windows to ventilate camper for any unusual odors such as
propane or other.
2. Be sure propane container has fuel and valve is turned open.
3. Release thermostat from OFF position .
4. Set thermostat to 5 to 8 degrees above room temperature.
5. Blower will start in 0 to 15 seconds, run for 30 seconds during
heat chamber PURGE cycle, to remove any propane vapor from
chamber.
6. Second cycle, blower continues to run, module board will; (a)
send spark to the burner tube; (b) open valve to release propane to
the burner tube.
7. Ignition attempt will be for 7 seconds.
8. Failing to ignite, board will make 2 more attempts to light the
burner and then go to lock-out.
9. If after (3) attempts with no ignition, drop thermostat to lowest
setting, wait 1 minute and repeat the same steps, 3 to 9.
10. After burner lights, set thermostat at desired at desired setting.
11. To shut burner down, move thermostat to lowest setting or OFF.
12. Blower will continue to run for about 2 minutes until heat is
removed from chamber.
This furnace is equipped with a 12 volt shut-off switch. With switch
turned “OFF”, furnace will NOT operate, propane will not flow to
burner nor will furnace operate. To locate this switch, a cabinet
panel may need to be removed.
NOTE; During initial firing of this furnace, a burn-off of excess paint
and oils remaining from manufacturing process may cause
“smoking” for five to ten minutes. Your dealer may have already
performed a “burn-off”.
A. Use only your hand to turn the handle on the manual shut off
valve. Never use tools. If the handle will not turn by hand,
don’t try to repair it, call a qualified service technician. Force
or attempted repair may result in a fire or explosion.
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
WARNING
!
PDF created with pdfFactory trial version www.pdffactory.com