APRS 51Track X1C3
GPS/Track/DIGI/BT/USB
Return command list
*** APRS-X1C2-20161003 BH4TDV ***
POWER: 4.7V TEMP: ----- Pressure: -----
AT+HELP=1
AT+DEMO=1
AT+CALL=NOCALL
AT+SSID=9
AT+TIME=30
AT+BEACON=1,!,3134.80N,/,12020.99E,>,X1C2
-> CMD ERR ! Try Enter
Command description
*** APRS-X1C2-20161003 BH4TDV ***
POWER: 4.7V TEMP: ----- Pressure: -----
The first line returns the firmware version number, battery voltage, temperature, and air pressure.
The air pressure and temperature are both installed to display the data.
CommandAT+HELP=1 Enter
Description: List all commands.
Command: AT+DEMO=1 Enter
Description: Use this setting to restore the motherboard defaults.
Command: AT+CALL=NOCALL Enter
Description: Set the beacon call sign, the default call sign is NOCALL, uppercase, up to 6 digits.
Command: AT+SSID=9 Enter
Description: Set the beacon SSID, the default is 9, the parameter value range is 0-15.
Command: AT+TIME=30 Enter
Description: Set the interval for transmitting beacons at regular intervals. The parameter value ranges from 0 to 65535
seconds. The default is 30 seconds for easy testing.
Command: AT+BEACON=1, !, 3143.55N, /, 12020.66E, >, X1C