Vernacare Vortex - Fault 10: Machine Not Clean Internally

Vernacare Vortex
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
Product stock
has large
particle size –
over 10 mm
Lack of water in the
hopper
Check isolation stop valve is open.
Check water pump is operating –
See fault 3.
Check non-return valve is sealing –
Replace.
Check float valve is not blocked – Clean.
Check water filters are not blocked –
Clean.
Blockage in lid spray
Check spray washer for blockage – Clean.
Check lid arm water inlet block for
blockage – Clean.
Check connection of pipe to lid arm for
blockage - clean
Blockage in water feed
pipe work.
Check pipes from water pump for
blockage – Clean.
Check water pump feed pipe for
blockage – Clean.
Check connection of pipe to lid arm
for blockage – Clean.
Diaphragm outlet
failure.
Check diaphragm condition – Replace.
Check solenoid water valve is operating –
Replace.
Check water solenoid valve filters for
blockage – Clean.
Check diaphragm valve spring is not
damaged or detached – Replace.
Blocked drain.
`BLOCKED DRAIN`
Drain is blocked – Clean.
Service drain is blocked – Clean.
Blade is worn.
Check blade edges for damage –
Replace.
3 Phase motor rotating
in wrong direction.
Check direction of cutter blade rotation –
Clockwise when viewed from above –
Reverse wiring as necessary.
Fault 10