56
3.7.18 spanning-tree recovery
Description
Recovery
Syntax
spanning-tree recovery interval <interval>
Parameter
Name
Description
interval
The interval
interva
Interval : 30-86400> Range in seconds
3.7.19 spanning-tree transmit
Description
Transmit
Syntax
spanning-tree transmit hold-count <holdcount>
Parameter
Name
Description
hold-count
Max number of transmit BPDUs per sec
holdcount
<Holdcount : 1-10> 1-10 per sec, 6 is
default
3.8 sFlow Configure Command
3.8.1 sflow
Description
Enables/disables flow sampling on this port.
Syntax
sflow [ <range_list> ]
Parameter
Name
Description
< range_list >
Sampler instance
3.8.2 sflow agent-ip
Description
The agent IP address used as agent-address in UDP datagrams. Defaults
to IPv4 loopback address.
Syntax
sflow agent-ip { ipv4 <ipv4_addr> | ipv6 <ipv6_addr> }
Parameter
Name
Description
< ipv4_addr >
Ipv4 address
< ipv6_addr>
ipv6 address
3.8.3 sflow collector-address
Description
Sflow runtime, see sflow_icli_functions
Syntax
sflow collector-address [ receiver <range_list> ] [ <word> ]
Parameter
Name
Description
< range_list >
Sampler instance
3.8.4 sflow max-datagram-size
Description
Statistics flow Maximum datagram size.
Syntax
sflow max-datagram-size [ receiver <range_list> ] <200-1468>
Parameter
Name
Description
<range_list>
receiver list
<200-1468>
packet byte
3.8.5 sflow max-sampling-size
Description
Specifies the maximum number of bytes to transmit per flow sample.
Syntax
sflow max-sampling-size [ sampler <range_list> ] [ <14-200> ]