EasyManua.ls Logo

Versa Technology VX-IGP-1204F - Poe Priority; Poe Reset; Poe Schedule

Versa Technology VX-IGP-1204F
92 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
80
3.21.7 poe priority
Description
Set PoE port priority
Syntax
poe priority <priority>
Parameter
Name
Description
critical
Set priority to critical.
high
Set priority to high.
low
Set priority to low.
3.21.8 poe reset
Description
Set PoE power reset time.
Syntax
poe reset <Hour> <Minute> <range_list>
Parameter
Name
Description
<0-23>
Hour
<0-59>
Minute
<range_list>
Day(s).(1:Sunday, 2:Monday, 3:Tuesday,
4:Wednesday, 5:Thuesday, 6:Friday,
7:Saturday)
3.21.9 poe schedule
Description
Set PoE power scheduling during the week.
Syntax
poe schedule <Day> <range_list>
Parameter
Name
Description
fri mon sat sun thu
tue wed
Day
<range_list>
There are 48 time interval one day. Each
interval has 30 minutes.
( [1]<00:00-00:29>
[2]<00:30-00:59>[3]<01:00-01:29> ...
[47]<23:00-23:29> [48]<23:30-23:59>).

Table of Contents

Other manuals for Versa Technology VX-IGP-1204F