EasyManua.ls Logo

Vertex Standard VX-2000V - Receiver Squelch Threshold Adjustment; Restore Original Channel Data

Vertex Standard VX-2000V
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Alignment
able DCS code 627 (encode), and download
this data to the transceiver.
r With the AF generator still set to zero, key the
transmitter, and adjust VR1005 (MAIN Unit)
for ±900 Hz deviation on the DCS signal (with-
in 100 Hz).
Receiver Squelch Threshold
r Set the transceiver to channel 2. Set the RF sig-
nal generator to the same frequency (147.000
for version A, 161.000 MHz for version C). Set
the signal generator’s output to -8 dBµ.
r Adjust VR1006 (MAIN Unit) clockwise until
the squelch just closes, and then counterclock-
wise until the squelch just opens.
r Turn off the signal generator, and confirm that
the squelch again closes when the RF input
signal disappears.
Restore Original Channel Data
r When all alignment steps have been complet-
ed, re-load the original channel data from your
computer’s disk, and download it to the trans-
ceiver.

Related product manuals