Liebert®
GXT4 UPS
Installer/User Guide
120V/208V, 500VA 3000VA

Table of Contents

Questions and Answers

  • S
    Sara LandryAug 9, 2025
    Why does my Vertiv Liebert GXT4-2000RT120 UPS have reduced battery backup time?
    • N
      Nicholas BrownAug 9, 2025
      The Vertiv UPS might have reduced battery backup time because the batteries are not fully charged. To resolve this, keep the UPS plugged in continuously for at least 24 hours to recharge the batteries. Alternatively, the UPS could be overloaded, so check the load level indicator and reduce the load. Lastly, the batteries may not be able to hold a full charge due to age, in which case you should replace them.
  • J
    Joseph LamAug 15, 2025
    Why is the battery indicator illuminated on my Vertiv Liebert GXT4-2000RT120?
    • O
      Oscar RogersAug 15, 2025
      The battery indicator illuminates when the Vertiv UPS is operating from battery mode. This can occur if the UPS is not securely plugged into the wall receptacle, so ensure it is properly connected. It can also happen if the UPS input protection fuse has blown or opened, in which case you should save data, close applications, replace the UPS input fuse, and then restart the UPS. Finally, the mains power may be out of tolerance, so you should ensure the mains supply voltage is within acceptable limits for the UPS, and save data and close applications.
  • J
    jreidAug 21, 2025
    How to fix a Vertiv Liebert GXT4-2000RT120 that fails to start?
    • W
      williamsluisAug 21, 2025
      The Vertiv UPS might fail to start because it is short-circuited or overloaded. Ensure the UPS is off, disconnect all loads, and make sure nothing is lodged in the output receptacles. Also, verify that the loads are not defective or shorted internally. Another reason could be that the batteries are not charged enough or not connected. Check to ensure the internal battery is connected; if not, make the connection and try to start the unit. If the battery is connected, leave the UPS connected to input power for 24 hours to recharge the batteries, then try to start the unit.
  • A
    Ana HarrisAug 27, 2025
    What to do if the battery indicator is flashing on my Vertiv UPS?
    • K
      Kevin PetersonAug 27, 2025
      The flashing battery indicator on your Vertiv UPS indicates that the battery source is not available, which is accompanied by a continuous horn. Check the battery connections, completely power down, and then restart the UPS. If the battery circuit opens while the UPS is running, it will be detected during the next battery test.
  • A
    andrea96Sep 2, 2025
    Why is the bypass indicator flashing on my Vertiv UPS?
    • R
      Rick FrazierSep 2, 2025
      The bypass indicator flashes on the Vertiv UPS because the voltage or frequency is outside acceptable limits, disabling the bypass. The AC input powers the PFC input and serves as the bypass source. If the AC is present but the voltage or frequency exceeds the acceptable range for safe operation with a load, the bypass will be disabled, and this indicator will flash, indicating that the bypass is unavailable.

Summary

1 IMPORTANT SAFETY PRECAUTIONS

UPS Safety Notes

Important safety guidelines for operating the UPS unit and its components.

Battery Safety

Critical warnings and precautions for handling UPS batteries to prevent shock and explosion.

2 GXT4 DESCRIPTION

2.6 Operating Modes

Description of the different operational modes of the GXT4 UPS.

3 INSTALLATION

3.4 Installing the UPS

General instructions for installing the UPS unit.

3.4.1 Tower Installation

Step-by-step guide for installing the UPS in a tower configuration.

3.4.2 Rack Installation

Guidelines for installing the UPS in a rack enclosure.

3.4.4 Connecting to AC Mains and Loads

Procedure for connecting the UPS to power and connected equipment.

4 OPERATION AND DISPLAY PANEL

LED Indicators

Detailed descriptions and functions of the various LED indicators on the UPS.

Control Buttons

Explanation of the function of each control button on the UPS panel.

5 OPERATION

5.1 Startup Checklist

Pre-operation checks to ensure the UPS is ready for startup.

5.2 Starting the UPS

Step-by-step instructions for powering on the GXT4 UPS.

5.3 Performing a Manual Battery Test

Procedure to initiate and perform a manual test of the UPS battery.

5.4 Performing Manual Bypass

How to manually transfer the connected load to the internal bypass.

5.5 Shutting Down the GXT4

Procedure for safely powering off the GXT4 UPS unit.

6 COMMUNICATION

7 MAINTENANCE

Battery Safety Precautions

Safety guidelines for working with UPS batteries.

7.1 Replacing the Internal Battery Pack

Instructions for safely replacing the internal battery pack of the UPS.

7.1.1 Battery Replacement Procedures

Detailed steps for replacing the internal UPS battery pack.

8 TROUBLESHOOTING

8.1 Symptoms that Require Troubleshooting

Indicators and alarms that suggest the UPS requires attention.

8.1.1 Faults

Description of displayed faults, their causes, and corrective steps.

8.1.2 Audible Alarm

Description of audible alarms and their corresponding UPS operating conditions.

8.2 Troubleshooting UPS Issues

A table guiding users through common UPS problems and their solutions.

APPENDICES

Appendix A: Technical Support

Contact information and resources for technical assistance with the Liebert GXT4.

Vertiv Liebert GXT4-2000RT120 Specifications

General IconGeneral
BrandVertiv
ModelLiebert GXT4-2000RT120
CategoryUPS
LanguageEnglish