press on/off button to turn on the machine under turn off status press the on/off
button to exit setting under ice thickness setting and filling water adjust status
Mode button:
Switch the ice making program
Clean / Set Button:
Press to clean status under machine turn off status
+/reservation button:
press to ice thickness adjust under pressure equilibriummaking iceunload ice
ice full status
click to increase 1, long press the button to increase continuously under ice
thickness adjust status
click to reservation time setting status under turn off status
-/light button:
click to decrease 1,long press the button to decrease continuously under ice
thickness adjust status
8.Fault codes
E-01.ice full button falut, skate board not back in position properly or ice full button
damage
E-02.making ice over time,can’t detect ice thickness 5 times continuously
E-03.unload ice over time,can’t detect ice full button action within 6mintues unload
ice 3times continuously
E-04.high temperature fault,condensation temperature higher than setting
temperature
E-05.lack of water
E-06.high pressure
E-07.condensation sensor fault
Instruction: when the machine is in the “lack-water protection condition, it can
restart automatically after the sink is filled with appropriate water. If other faults
cause the machine to stop, press the start button or supply power again after