ALARM
MAIN
REASON
KEYPAD
SIGNALLING
SOLUTIONS
The machine cannot fill
the steam boiler within
90 seconds.
Key 1B and icon T
flashing.
Switch the machine OFF and ON to
restart the auto-fill function.
If not solved:
• check proper flow of inlet water
from the mains or from the tank;
• check the water stop valve or
the tank valve;
• check the pump and the self-lev-
elling valve,
• check potential leaks;
• check the level probe: the pres-
ence of limescale and the integ-
rity of the plastic insulation can
all effect the auto-fill function.
The machine can-
not reach the setpoint
temperature within 40
minutes. It can involve:
• the steam boiler;
• the coffee boiler;
• the coffee group.
Key 1B and icon H
flashing.
Firstly understand witch part is
affected (for example, if there is
not steam, the part affected is the
steam boiler).
Then, in relation to the proper part:
• check the thermo-fuse or
high-limit thermostat continuity.
• check the heating element con-
tinuity and integrity.
• check the LEDs on the control
unit and/or on the static relay.
• check connections.
The control unit does
not receive the signal
from a probe.
It can involve:
• the steam boiler
pressure transducer;
• the coffee boiler
temperature probe;
• the coffee group
temperature probe;
• the Easycream tem-
perature probe.
Key 1A, key 1C,
icons T and H
flashing.
Check the probe or transducer and
its connection to the control unit.
A probe has a short
circuit. It can involve:
• the steam boiler
pressure transducer;
• the coffee boiler
temperature probe;
• the coffee group
temperature probe;
• the Easycream tem-
perature probe.
Key 1A, key 1C,
icons T and H
flashing.
Check the probe or transducer and
its connection to the control unit.