166
ALARM
MAIN
REASON
KEYPAD
SIGNALLING
SOLUTIONS
The control unit cannot
sense the water level in
the steam boiler.
/
On the level probe:
• check the presence of limescale;
• check the integrity of the plastic
insulation.
The machine cannot fill
the coffee boiler within
10 seconds.
/
The control unit cannot receive the
signal from the flowmeter during
the FILLING procedure:
• check proper flow of inlet water
from the mains or from the tank.
• check the water stop valve or
the tank valve.
• check potential leaks.
• check the flowmeter connection
to the control unit.
• check the presence of a block-
age: in the flowmeter, its metal-
lic input filter, the restrictor and
the not-return valve.
Key 1A, key 1C and
icon H flashing.
General error on
memory parameters.
/
Check if the error disappears by
switching the machine OFF and ON.
If not:
• reset all machine parameters
with the RESET PARAMETERS pro-
cedure;
• update the firmware or re-install
the same firmware version;
• change the control unit.
General error on
memory counters.
/
Check if the error disappears by
switching the machine OFF and ON.
If not:
• reset all machine counters with
the RESET COUNTERS procedure;
• update the firmware or re-install
the same firmware version;
• change the control unit.
The CR1220 3 Volt bat-
tery has been dis-
charged.
/
Change the CR1220 3 Volt battery
on the control unit.
The machine is due for
its periodic mainte-
nance.
/
To delete the warning, enter the
Alarm Setting menu in the Victoria
Arduino E1 APP and press the reset
button to reset the cycle counter.
Inlet water pressure
less than 0,5 bar for at
least 15 seconds.
/ Check the mains pressure.