8. Technical specifications
MultiPlus-II 48/3000/35-32 230V GX 48/5000/70-50 230V GX
PowerControl & PowerAssist Yes
Transfer switch 32A 50A
Maximum AC input current 32A 50A
INVERTER
DC Input voltage range 38 – 66 V
AC Output voltage 230 V ± 2%
AC output frequency 50 Hz ± 0,1% (1)
AC output current 11A 19A
Cont. output power at 25°C (3) 3000 VA 5000 VA
Cont. output power at 25°C 2400 W 4000 W
Cont. output power at 40°C 2200 W 3700 W
Cont. output power at 65°C 1700 W 3000 W
Max apparent feed-in power 3000 VA 5000 VA
Peak power 5500 W 9000 W
Maximum efficiency 95% 96%
Zero load power 11 W 18 W
Zero load power in AES mode 7 W 12 W
Zero load power in Search mode 2 W 2 W
CHARGER
AC Input voltage range GENERAL 187-265 V
AC Input frequency range 45 – 65 Hz
Charge voltage 'absorption' 5.6 V
Charge voltage 'float' 55.2 V
Storage mode 52.8 V
Max. battery charge current (4) 35 A 70 A
Battery temperature sensor Yes
Compatible battery chemistries Lead-acid, Lithium, Zinc-Bromine and others (5)
GENERAL
Auxiliary AC output Yes (32A)
External AC current sensor (optional) 50A 100A
Programmable relay (6) Yes
Protection (2) a - g
Inbuilt GX device Yes
VE.Bus communication port Yes
VE.Can port Yes
VE.Direct port Yes
USB port Yes
Ethernet port Yes
General purpose communication port Yes, 2x
Remote on/off terminal Yes
Operating temperature range -20 to +65°C (fan assisted cooling)
MultiPlus-II inverter/charger off-grid Australia
Page 17 Technical specifications